Seplos 25.6V 280Ah LiFePO4 Lithium Phosphate Battery Pack DIY Kits Solar Energy Storage Ten Year Warranty
Item | Specifications |
Rated energy(kWh) | 7.16KWh |
Configuration | 1P8S |
Nominal Voltage(V) | 25.6V |
Nominal Capacity(Ah) | 280Ah @0.5C discharge current 25±2℃ |
Discharge Cut-off Voltage (V) | 20.8V |
Standard charge/discharge Current (A) | 100A @25±2℃ (Recommended) |
Max Standard charge/discharge Current (A) | 200A @25±2℃ |
Working Temperature | 0~50℃(Charge) -10~50℃(Discharge) |
Weight(Kg) | 72Kg±3kg |
Dimension(mm) | (450)×(440)×(251)mm |
Recommended SOC Range | 15-95% |
Communication mode | CAN (Default)or RS485 |
- Suitable for SEPLOS 3.2V 280Ah LiFePO4 prismatic cells.
- Battery cell is made from lithium iron phosphate (LiFePO4).
- Specially designed plastic cell holder features fire proof and insulation.
- BMS has over-discharge, over-charge, over-current, high and low temperature warning and protection functions.
- BMS monitors the charge and discharge state, and balance the current and voltage of each cell.
- BMS comes with upper computer system for real-time cell and pack voltage, current, temperature, and battery status monitoring and recording.

Brand | Protocol | Communication | Versions |
Pylontech | CAN-Bus-Protocol-PYLON | CAN | V1.3 |
Goodwe | Goodwe Communication Protocol | CAN | V1.5 |
Lolis | CAN Communication Protocol | CAN | V1.0 |
Sofar | BMS CAN BUS Protocol | CAN | V1.0 |
Growatt-SPF | Growatt BMS CAN-Bus-Protocol-Low-Voltage | CAN | V1.05 |
Growatt-SPH | Growatt BMS Communication Protocol Of Growatt Low Voltage Battery | CAN | V1.01 |
SMA | FSS-ConnectingBat-TI-EN-20W | CAN | V2.0 |
Victron | Can-Bus_Bms_Protocol | CAN | V1.0 |
LUXPOWER | Luxpowertek Battery CAN Protocol | CAN | V1.0 |
Studer | Technical Specification Studer BMS Protocol | CAN | V1.03 |
TBB | TBB BMS CAN Communication V1.02 | CAN | V1.02 |
Deye | CAN-Bus-Protocol-PYLON-V1.3 | CAN | V1.0 |
Sorocec | 2_CAN Protocol 1.0 | CAN | V1.0 |
MEGAREVO | Hybrid Inverter_5K_BMS Protocol V1.01 | CAN | V1.01 |
Amensolar | CAN-Bus-Protocol-PYLON | CAN | V1.0 |
Sacolar | Growatt BMS CAN-Bus-Protocol-Low-Voltage | CAN | V1.05 |
MUST | PV1800F-CAN Communication Protocol | CAN | V1.04.04 |
AFORE | Luxpowertek Battery CAN Protocol | CAN | V1.0 |
Pylontech | RS485-Protocol-Pylon-Low-Voltage | 485 | V3.5 |
Voltronic Power | Voltronic Inverter And BMS 485 Communication Protocol | 485 | V1.0 |
SRNE | PACE BMS Modbus Protocol For RS485 | 485 | V1.3 |
Deye | RS485-Protocol-Pylon-Low-Voltage | 485 | V1.0 |
Growatt-SPF | SPF BMS RS485 | 485 | V2.01 |